Abstract

R601a/R245fa mixture is one kind of promising working fluid in ORC. In this study, the thermal decomposition mechanism of R601a/R245fa mixture was studied by reactive molecular dynamic simulation (ReaxFF-MD) and density function theory (DFT). In the R601a/R245fa mixed working fluid system, pyrolysis begins with the CC bond breaking of R601a, generating a large number of CH3 radicals, which further decompose to produce a certain amount of H radicals. Due to the presence of R245fa, the hydrogen extraction reactions between CH3, H radicals and R601a, which have low energy barriers were inhabited to a certain extent. The addition of R245fa reduces the generation of small molecule flammable gases such as H2 and CH4, however, it increases the risk of HF generation. When the molar ratio of R245fa exceeds 0.5, pyrolysis will cause more serious HF corrosion problems than pure R245fa.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.