Abstract
We retrospectively reviewed a consecutive single surgeon series of 57 Ascension pyrocarbon proximal interphalangeal joint arthroplasties, with a mean follow-up of 7.1 years (range 2 years to 11 years 6 months). We assessed the ranges of motion, deformity, stability and pain of the operated joints, grip strength of the hand and patient satisfaction. Of the cases, 44 were for osteoarthritis, five for rheumatoid arthritis and eight for post-traumatic arthritis. The median post-operative active arc of motion was from 0° to 60°. The median post-operative visual analogue pain score was 0.3 out of ten. Thirty six of the joints had no complications; 14 had minor complications (squeak, slight swan neck); three required early reoperation (joint release, flexor tenodesis); and five required implant removal. A total of 69% of our patients would have the same operation if they had to make the decision again. The Kaplan-Meier survival method estimates the mean implant survival to be 10.7 years (95% confidence intervals 9.96-11.37 years). All five failures occurred during the first 2 years.Level of evidence 4 (Case-series).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.