Abstract

This paper proposes a new PWM harmonic current based diagnostic method for the interturn short-circuit fault (ITSCF) of fault tolerant permanent magnet synchronous motor (FTPMSM) drives, which is able to detect and locate the fault phase for the system even in fault tolerant operation (FTO) condition. The ITSCF model for the H-bridge drive based FTPMSM system is firstly proposed, while the high-frequency (HF) harmonic current component and impedance are analyzed both in normal and ITSCF conditions. The PWM harmonic current based fault diagnostic approach is then proposed to confirm the fault phase, which consists of the band-pass filter, the periodic root mean square (RMS) calculator and the fault identification. The resulting fault diagnostic method has simple structure, fast fault detection, good robustness and low computational burden, which can achieve the ITSCF for the FTPMSM system both under normal and FTO conditions. The effectiveness of the ITSCF diagnostic method is verified via the six-phase FTPMSM experimental platform, which can provide a guideline for the ITSCF mitigation and FTO of the FTPMSM system.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call