Abstract

In this paper, Common-mode voltage (CMV) is responsible for overvoltage stress to the winding insulation and bearing damage of an AC motor. High dv/dt of CMV causes leakage currents, which create noise problems to the equipment installed near the converter. This paper presented modulation strategy to eliminate CMV three level T-Type inverter (Zero CMV 3L T2I) that substantially eliminates CMV. The principles of selecting suitable triangle carrier signals for the T-Type is described. This PWM control method can mitigate the peak value to 95% as compared to the conventional sinusoidal pulse width modulation method. A prototype is constructed to verify the operating principle of the three-level T-Type inverter. Simulation and experimental results are presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.