Abstract

This paper investigates the shear strength and failure modes of steel-concrete-steel (SCS) sandwich composite member with Engineered Cementitious Concrete (ECC) and explores the influences of various shear connectors such as headed stud and bolt on shear behavior of SCS sandwich composite member by carrying out push-out testing program. Based on the test results in this study, the failure modes and the load-slip behavior of the specimens are investigated. In addition, the experimental results on the shear resistance of the headed stud connector with various connector spacing and numbers of connector is compared and explored.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.