Abstract

In the last decades several experimental tests were performed to analyse the seismic capacity of unreinforced masonry, mostly involving small size structural elements or small-scale building models, not accounting for the actual complexity of existing constructions. This paper illustrates experimental pushover tests on two very similar portions of an existing masonry building. The first portion was tested as built, while the second one was tested after a strengthening intervention with Composite Reinforced Mortar (CRM) system with Glass Fiber Reinforced Polymer (GFRP) components. The retrofit consisted in the application of a reinforced plaster on both sides of the walls of the first storey and on the external side only of the second storey, a solution that preserves the continuity of use. Comparisons between the experimental response of the two portions as well as the observed behaviour of the intervention at the first storey (both wall sides) and second storey (only outer side) provide very interesting insights and preliminary information on the degree of upgrading, essential steps to support the assessment of seismic vulnerability reduction.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.