Abstract
A suspension comprising of the three antibiotic substances amphotericin B, colistin sulfate and tobramycin sulfate is often used in clinical practice for the selective decontamination of the digestive tract of patients in intensive care. Since no detailed procedures, specifications or stability data are available for manufacturing this suspension, there may be discrepancies regarding formulation and stability of suspensions prepared in different pharmacies. The aim of this work is to develop a standardized formulation and to determine its stability under defined storage conditions. This would help guarantee that all patients receive the same preparation, therefore ensuring similar efficacy and improved safety. The first step in this process is to develop the required analytical tools to measure the content and purity of the drug substances in this complex mixture. In this paper, the development and validation of these tools as well as the development of the drug suspension formulation is described. The formulation comprises of Ampho-Moronal(®)-Suspension (Dermapharm) and a buffered, preservated aqueous solution of colistin sulfate and tobramycin sulfate. Two simple, well established high-performance liquid chromatography (HPLC) methods in the European Pharmacopoeia (EP) for impurity profiling of the two active ingredients amphotericin B and colistin sulfate were combined with a newly developed sample extraction procedure for the suspension. Sufficient selectivity and stability-indicating power have been demonstrated. Additionally, a new robust routine method was developed to determine possible degradation products of tobramycin sulfate in the investigated suspension. The specificity, precision, accuracy and linearity of the analytical procedures were demonstrated. The recovery rate was in the range of 90-110%. The precision results for the calculated impurities showed variation coefficients of <10%. The calibration curves were found to be linear with correlation of greater than 0.9994 for all components. The results show the suitability of the methods for the quality control analysis of the suspension.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.