Abstract

To investigate in a rat model of ventilation-induced lung injury whether metabolic changes in the lung are reflected by an increased purine concentration (adenosine, inosine, hypoxanthine, xanthine, and urate; an index of adenosine-triphosphate breakdown) of the bronchoalveolar lavage fluid and whether purine can, thus, indirectly serve as a marker of ventilation-induced lung injury. Prospective, randomized, controlled trial. Research laboratory. Forty-two male Sprague-Dawley rats. Five groups of Sprague-Dawley rats were subjected to 6 mins of mechanical ventilation. One group was ventilated at a peak inspiratory pressure of 7 cm H2O and a positive end-expiratory pressure of 0 cm H2O. A second group was ventilated at a peak inspiratory pressure of 45 cm H2O and a positive end-expiratory pressure of 10 cm H2O. Three groups of Sprague-Dawley rats were ventilated at a peak inspiratory pressure of 45 cm H2O without positive end-expiratory pressure. Before mechanical ventilation, two of these groups received intratracheal administration of saline or exogenous surfactant at a dose of 100 mg/kg and one group received no intratracheal administration. A sixth group served as the nonventilated controls. Bronchoalveolar lavage fluid was collected in which both purine concentration (microM; mean +/- SD) and protein concentration (mg/mL; mean +/- SD) were determined. Statistical differences were analyzed using the one-way analysis of variance (ANOVA) with a Student-Newman-Keul's post hoc test. Purine and protein concentrations were different between groups (ANOVA p value for purine and protein, <.0001). Both purine and protein concentrations in bronchoalveolar lavage fluid were increased in Group 45/0 (3.2 +/- 1.9 and 4.2 +/- 1.6, respectively) compared with Group 7/0 (0.4 +/- 0.1 [p < .05] and 0.4 +/- 0.2 [p < .001]) and controls (0.2 +/- 0.2 [p < .01] and 0.2 +/- 0.1 [p < .001]) and in Group 45/Na (5.8 +/- 2.5 and 4.2 +/- 0.5) compared with Group 7/0 (purine and protein, p < .001) and the controls (purine and protein, p < .001). Positive end-expiratory pressure prevented an increase in purine and protein concentrations in bronchoalveolar lavage fluid (0.4 +/- 0.3 and 0.4 +/- 0.2, respectively) compared with Group 45/0 (purine, p < .01; protein, p < .001) and Group 45/Na (purine and protein, p < .001). Surfactant instillation preceding lung overinflation reduced purine and protein concentration in bronchoalveolar lavage fluid (2.1 +/- 1.6 and 2.7 +/- 1.0) compared with Group 45/Na (purine, p < .001; protein (p < .01). Surfactant instillation reduced protein concentration compared with Group 45/0 (p < .01). This study shows that metabolic changes in the lung as a result of ventilation-induced lung injury are reflected by an increased level of purine in the bronchoalveolar lavage fluid and that purine may, thus, serve as an early marker for ventilation-induced lung injury. Moreover, the study shows that both exogenous surfactant and positive end-expiratory pressure reduce protein infiltration and that positive end-expiratory pressure decreases the purine level in bronchoalveolar lavage fluid after lung overinflation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call