Abstract

Data regarding wastewater purification by means of cold plasma in the biochemical department at Nizhny Tagil Steel Works are analyzed in the light of new information regarding the chain oxidation of hydrocarbons and their products. In chain oxidation initiated by cold plasma, oxygen-bearing products that do not undergo chain reactions are formed. Therefore, the chemical oxygen demand of plasma-treated wastewater cannot be reduced below 300—400 mg O/L.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.