Abstract

The aim of this work was to develop a method for purification of the spent 100/99Mo–99mTc generator free from non-isotopic impurities like Nb, Y, Zr and recovery of 99mTc using a Sephadex column and MEK solvent extraction technique, respectively. This study was done by performing simulation experiment with 98Mo(n,γ)99Mo solution doped with the radiotracers of the above said non-isotopic impurities. There was respective adsorption of non-isotopic impurities of Nb, Zr and Y on Sephadex column (99.99%; n = 3) and extraction 99mTc in MEK. The extraction efficiency of pure 99mTc (radionuclidic purity: 99.99%, n = 3) from various Mo solution was 97% (n = 3).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.