Abstract

The purification efficiency of biological removal of iron and manganese was probed by pilot tests. In this experiment, the raw water were iron concentration of 0.96~5.56 mg/L, manganese concentration of 0.87~2.38 mg/L, dissolved oxygen of 2~4 mg/L, pH value neutral. In the condition of filter speed of 6 m/h, the average removal rate of iron and manganese reached 97.6% and 90.9% respectively, the effluent concentration of Fe2+ and Mn2+ were keep in below 0.1 mg/L.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.