Underground parking structures often consist of flat slabs connected by columns, for which punching shear is often the most critical design criterion. In fire conditions, the punching load can increase due to restraint of the thermal curvature of the slab or due to the expansion of the columns. This increase of the punching load is discussed in the paper by means of a literature review. On the other hand, during fire the punching resistance of the slab decreases due to a gradual reduction of the material properties. This reduction in bearing capacity is studied by means of real scale fire tests, consisting of 6 slabs measuring 3.2×3.5×0.25m with a connected column stub and tested for punching shear with a specially designed loading frame. Two reference tests are executed at ambient temperature conditions and four slabs are submitted to ISO 834 curve for 120min. Comparison of the test data with the expected increased axial load due to thermal restraint found in the literature, shows a potential danger for premature punching failure of flat slab-column connections exposed to fire.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.