Abstract

AbstractThis article presents the results of an experimental program on two-way flat slabs with central loading. The slabs were designed according to the American Concrete Institute code. One slab without any modification was used as the control and four were strengthened with different carbon fiber–reinforced polymer (CFRP) grid configurations including one with preinstalled and three with postinstalled fiber–reinforced polymer (FRP) strengtheners. For strengthening, 8, 16, and 24 strengtheners were used. A method was developed for predicting maximum loading capacity in slabs strengthened with CFRP grids and epoxy resin used in drilled holes. The results of the experiments show that the proposed strengthening method enhances maximum loading and deformation capacities. Furthermore, the proposed strengthening method prevents brittle failures that may occur under vertical concentrated loadings. The dominant failure mode for flat slabs strengthened with FRP grids is found to be deboning of FRP grids due to t...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.