Abstract

Abstract Punching shear is a possible type of failure that occurs in reinforced concrete flat slabs, which can develop with an ultimate load below flexural capacity. Several researchers have studied the punching resistance of flat slabs over recent years. Although they have made great advances, there are codes that show different approaches to a singular design. Some codes show that there exist contradictions, even in the simplest situations, such as concentric loads. Most codes prescribe empirical expressions based in a theoretical model to analyze punching strength, but for flat slabs with holes around the column and shear reinforcement there are divergences between codes, justifying research in this area. This paper presents an experimental analysis of nine square reinforced concrete flat slabs under concentric loading (width: 1800 mm; thickness: 130 mm). The main variables used in the tests were: a) two square openings (150 mm) adjacent to the smallest side of the column and b) the use of shear reinforcement containing 3 layers, with 6 or 8 elements in each layer and radially distributed around the column. The research concludes that openings adjacent to the column affect punching shear strength, while the correct use of the shear reinforcement can minimize and even compensate this loss.

Highlights

  • IntroductionThe conventional structure system (slab-beam-column), for some situations, has been substituted by the slab-column system in civil construction projects

  • The conventional structure system, for some situations, has been substituted by the slab-column system in civil construction projects

  • All the slabs tested had punching shear failure, and the research was directed to this failure mode

Read more

Summary

Introduction

The conventional structure system (slab-beam-column), for some situations, has been substituted by the slab-column system in civil construction projects. The slab-column system does not have the support of the beams, where the slabs are supported directly onto the column This structural concept brings advantages, such as facilitating the use of the formwork in order to reduce cuts influenced by beams. This produces greater agility in the construction process with a decrease in costs regarding material waste. Rupturing due to punching failure from a flat structural element such as a slab or foundation element can occur with the application of a concentrated force on a particular area of this element, producing an intense shear force in the region. The punching failure can occur in buildings in regions between the column and slab, where the column is supported on a slab. This damage may occur in an abrupt and fragile manner, without giving warning

Objectives
Methods
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.