Abstract

The aim of this work is to study the behaviour of reinforced concrete flat slab structures under combined vertical and horizontal cyclic loading. A total of five specimens were cast and tested: a control specimen was punched without eccentricity, one specimen was tested under constant vertical loading and monotonically increased eccentricity until failure and the remaining three were tested under constant vertical load, at different shear ratios, and cyclic horizontal loading with increasing horizontal drift ratios. All slabs were similar, measuring 4.25×1.85×0.15m3. The reinforced concrete slab specimens were connected to two steel half columns by 0.25×0.25m2 rigid steel plates, prestressed against the slab using steel bolts, to ensure monolithic behaviour. The cyclic tests were performed using an innovative test setup that allows bending moment redistribution, line of inflection mobility, assures equal vertical displacements at the North-South borders and symmetrical shear forces. Results show that cyclic horizontal actions are very harmful to the slab–column connection, resulting in low horizontal drifts and energy dissipation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.