Abstract

The impact of a loss-of-coolant accident (LOCA) on a nuclear reactor is determined in its first phase by many events, one of them being the behavior of the reactor coolant pumps. In this case, a mixture of steam and water flows through the pumps. Experiments were carried out to examine the family of characteristics of geometrically scaled pumps (scale 1:5 and 1:4) within the relevant parameter range under such conditions. The presented results of steady-state experiments are compared with results of former projects. Besides flow and speed, the most significant parameters on two-phase pump performance are void fraction and system pressure. A brief comparison between steady-state and transient results is provided. The impact of the pump's behavior on the LOCA is demonstrated on the basis of blowdown calculations using various pump models and two-phase pump data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.