Abstract

Reference values were established for selected Doppler derived variables from a group of 40 normal Thoroughbred and Thoroughbred cross horses. Standard two-dimensional (2-D) images used for guiding the Doppler sampling site allowed accurate alignment with flow. Tricuspid inflow velocities during rapid filling (E) and atrial contraction (A) were significantly higher when recorded from a right parasternal angled view than from a right parasternal long-axis view. In 8 horses the tricuspid inflow peak A velocity was higher than the peak E velocity. The peak acceleration of blood flow was higher (P = 0.000) in the aorta (mean 8.01 m/s/s) than in the pulmonary artery (4.45 m/s/s). Significant differences were also noted in the pre-ejection period, ejection time and acceleration time between the 2 vessels. Horses with functional ejection murmurs had lower peak aortic acceleration and a longer acceleration time than horses without flow murmurs. Horses with filling murmurs over the left hemithorax had a significantly higher peak mitral E velocity than horses without such murmurs. Measurements from Doppler waveforms were repeatable and may prove useful in assessing ventricular function in this species.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.