Abstract

Separate systems and devices for the future accelerator complex are developed in the framework of the NICA project. The multivariant injection scheme with five pulsed power supply sources of the inflector plates will be applied for the Nuclotron Booster. The startup variant includes one source with the largest maximum voltage equal to 62 kV. This study presents the pulsed power-supply source of the inflector plates for the Nuclotron Booster injection system. The equipment and the high voltage source control system are described and the results of testing with equivalent load are given.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.