Abstract

The use of slow (∼1 Hz) flow oscillation imposed on a stationary flow of liquid has been shown to enhance shear stresses imposed on a surface and to mitigate fouling or enhance cleaning. Examples of the application of pulsed flow are presented in this paper. A new measuring technique in combination with tailored CFD simulations was developed for monitoring the cleaning of complex piping equipment with pulsed flow. A time-independent and isotropic approach to model the wall shear stress is introduced. The optical monitoring procedure uses a model food soil consisting of starch as matrix material and phosphorescent zinc sulfide crystals as optical tracer. Investigations of pulsed flow cleaning published prior to this work focused on tests with straight pipes, whereas difficulties in industrial cleaning operations more often arise while operating piping systems and plant components with complex geometries. Therefore cleaning experiments were performed in a CIP test rig simulating industrial cleaning processes. The results with pulsed flow show an enhancement of cleaning efficiency at locations difficult to access using stationary flow.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.