Abstract

Abstract Background Radiofrequency catheter-ablation in the left ventricular summit region is a challenging procedure due to proximity to the coronary arteries. Pulsed field ablation, a novel non-thermal ablation modality, does not cause damage to coronary arteries, and may be used in the left ventricular summit region. Case Summary We describe a 45-year-old symptomatic patient with epicardial left ventricular summit premature ventricular complexes. Successful ablation of the focus was achieved by pulsed field ablation via a subxiphoid epicardial approach. Radiofrequency ablation would most likely have been ineffective due to the epicardial fat layer and potentially unsafe due to the proximity to the coronary arteries. Six months after ablation the patient was asymptomatic and without ventricular ectopy. Discussion For the first time epicardial pulsed field ablation was successfully used for ablation of left ventricular summit extrasystole, where radiofrequency ablation could not be used because of the proximity of the coronary arteries. We conclude that pulsed field ablation might be a feasible option for this indication.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.