Abstract
Eddy-current nondestructive evaluation commonly carried out using single frequency time harmonic excitations, but a pulsed excitation offers a simple and effective alternative. The pulse signals have been calculated for a probe coil whose current rises and falls exponentially, approximating a square wave when the exponential time constant is small. Predictions of the induced electromotive force (EMF) across a coil above a half-space conductor and of the magnetic field on the coil axis have been compared with experiments. The comparison shows excellent agreement between theory and experiment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.