Abstract

Carotid stenosis involves narrowing of the lumen in the carotid artery potentially leading to a stroke, which is the third leading cause of death in the United States. Several recent investigations have found that plaque structure and composition may represent a more direct biomarker of plaque rupture risk compared with the degree of stenosis. In this study, pulse wave imaging was applied in 111 (n = 11, N = 13 plaques) patients diagnosed with moderate (>50%) to severe (>80%) carotid artery stenosis to investigate the feasibility of characterizing plaque properties based on the pulse wave-induced arterial wall dynamics captured by pulse wave imaging. Five (n = 5 patients, N = 20 measurements) healthy volunteers were also imaged as a control group. Both conventional and high-frame-rate plane wave radiofrequency imaging sequences were used to generate piecewise maps of the pulse wave velocity (PWV) at a single depth along stenotic carotid segments, as well as intra-plaque PWV mapping at multiple depths. Intra-plaque cumulative displacement and strain maps were also calculated for each plaque region. The Bramwell-Hill equation was used to estimate the compliance of the plaque regions based on the PWV and diameter. Qualitatively, wave convergence, elevated PWV and decreased cumulative displacement around and/or within regions of atherosclerotic plaque were observed and may serve as biomarkers for plaque characterization. Intra-plaque mapping revealed the potential to capture wave reflections between calcified inclusions and differentiate stable (i.e., calcified) from vulnerable (i.e., lipid) plaque components based on the intra-plaque PWV and cumulative strain. Quantitatively, one-way analysis of variance indicated that the pulse wave-induced cumulative strain was significantly lower (p < 0.01) in the moderately and severely calcified plaques compared with the normal controls. As expected, compliance was also significantly lower in the severely calcified plaques regions compared with the normal controls (p < 0.01). The results from this pilot study indicated the potential of pulse wave imaging coupled with strain imaging to differentiate plaques of varying stiffness, location and composition. Such findings may serve as valuable information to compensate for the limitations of currently used methods for the assessment of stroke risk.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call