Abstract

Pulse Train/spl trade/ control technique is introduced and applied to flyback converter operating in discontinuous conduction mode (DCM). In contrast to the conventional pulse width modulation (PWM) control scheme, the principal idea of Pulse Train is to achieve output voltage regulation using high and low power pulses. The proposed technique is applicable to any converter operating in DCM. However, this work mainly focuses on flyback topology. In this paper, the main mathematical concept of the new control algorithm is introduced and simulations as well as experimental results are presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.