With the popularization of pulse wave signals by the spread of wearable watch devices incorporating photoplethysmography (PPG) sensors, many studies are reporting the accuracy of pulse rate variability (PRV) as a surrogate of heart rate variability (HRV). However, the authors are concerned about their research paradigm based on the assumption that PRV is a biomarker that reflects the same biological properties as HRV. Because PPG pulse wave and ECG R wave both reflect the periodic beating of the heart, pulse rate and heart rate should be equal, but it does not guarantee that the respective variabilities are also the same. The process from ECG R wave to PPG pulse wave involves several transformation steps of physical properties, such as those of electromechanical coupling and conversions from force to volume, volume to pressure, pressure impulse to wave, pressure wave to volume, and volume to light intensity. In fact, there is concreate evidence that shows discrepancy between PRV and HRV, such as that demonstrating the presence of PRV in the absence of HRV, differences in PRV with measurement sites, and differing effects of body posture and exercise between them. Our observations in adult patients with an implanted cardiac pacemaker also indicate that fluctuations in R-R intervals, pulse transit time, and pulse intervals are modulated differently by autonomic functions, respiration, and other factors. The authors suggest that it is more appropriate to recognize PRV as a different biomarker than HRV. Although HRV is a major determinant of PRV, PRV is caused by many other sources of variability, which could contain useful biomedical information that is neither error nor noise.

Highlights

  • Main text Recently, many studies have reported the accuracy of pulse rate variability (PRV) as a surrogate of heart rate variability (HRV) [1–4]

  • The authors are concerned about the research paradigm based on the assumption that PRV is a biomarker that reflects the same biological properties as HRV. This assumption could undermine the physiological and pathological value of PRV. Both PPG pulse wave and ECG R wave reflect the periodic beating of the heart

  • Despite the absent HRV and its flat power spectrum, fluctuations were observed in the pulse transit time (PTT) measured as the time from the ECG R wave to the PPG presystolic foot point

Read more

Summary

Introduction

Main text Recently, many studies have reported the accuracy of pulse rate variability (PRV) as a surrogate of heart rate variability (HRV) [1–4]. Both PPG pulse wave and ECG R wave reflect the periodic beating of the heart.

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.