Abstract

Due to corrosive and hostile environment, in-service conductive structures are prone to subsurface corrosion which has posed a severe threat to structural integrity and safety. Although Pulsed eddy current testing (PEC) has been found advantageous over other Electromagnetic Non-destructive Evaluation (ENDE) techniques particularly in detection and characterisation of subsurface defects in conductive structures, it is subject to technical drawbacks. In light of this, in this paper, Pulse-modulation eddy current technique (PMEC) is proposed in an effort to enhance the inspection sensitivity to subsurface corrosion and quality of corrosion imaging. Closed-form expressions of PMEC responses to subsurface corrosion are formulated via the Extended Truncated Region Eigenfunction Expansion (ETREE) modelling. A series of simulations are subsequently conducted to analyse the characteristics of PMEC signals and inspection sensitivity. Following this, experiments of PMEC for evaluation and imaging of subsurface corrosion are carried out. Through theoretical and experimental investigation, it has been found that PMEC is advantageous over PEC in terms of evaluation sensitivity and quality of corrosion imaging.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call