Abstract

The principal objectives of this study were: to determine, quantitatively, coal dust retention times in the dog lung; to test the appropriateness of a pulmonary retention model which incorporates first order rate coefficients obtained from in vitro and in vivo experiments on neutron-activated coal; to acquire a temporal description of the pulmonary disposition of the retained coal dust, and to compare the behavior of two different Pennsylvania coals in the foregoing regards. The principal findings include: retention half-times for both coals of approximately 2 years following single, hour-long exposures; a vivid association of the retained coal dust with the pulmonic lymphatics; and a general validation of the retention model.