Abstract

The aim of our study was to determine an optimal slice thickness that was efficient in revealing bronchial imageology of pulmonary nodules (PNs) on multi-slice spiral computed tomography (MSCT) images preliminarily. Fifty-four patients with 62 PNs (diameter ≤ 3 cm) underwent multidetector-row computed tomography of the chest in a single-breath-hold technique. The raw data were acquired with a collimation of 0.625 mm. Three sets of contiguous images were reconstructed with 1-, 2-, and 5-mm slice thickness, respectively. Bronchial imageology of SPNs on the CT images presented in 1-, 2-, and 5-mm slice thickness was compared. Using the 1-mm sections as the gold standard, an optimal slice thickness in revealing bronchial imageology of PNs was determined. Bronchial imageology of PNs on the CT images presented in 1 mm slice thickness involved 85 bronchi (35 second-fourth generation bronchi; 50 fifth-eighth generation bronchi). Bronchial imageology on 2-mm-thick sections was as same as that on 1-mm-thick sections in 34 second-fourth generation bronchi. No statistically significant difference in number of second-fourth generation bronchi with same bronchial imageology was found between that on 2-mm-thick images and 1-mm-thick images (P = 0.836 > 0.05). Bronchial imageology on 5-mm-thick sections was as same as that on 1-mm-thick sections in 24 second-fourth generation bronchi. There was statistically significant difference in number of second-fourth generation bronchi with same bronchial imageology between that on 5-mm-thick images and 1-mm-thick images (P = 0.026 < 0.05). Bronchial imageology on 2-mm-thick sections was as same as that on 1-mm-thick sections in 38 fifth-eighth generation bronchi. There was statistically significant difference in number of fifth-eighth generation bronchi with same bronchial imageology between that on 2-mm-thick images and 1-mmthick images (P = 0.029 < 0.05). Bronchial imageology on 5-mm-thick images was as same as that on 1-mm-thick images in 31 fifth-eighth generation bronchi. There was statistically significant difference in number of fifth-eighth generation bronchi with same bronchial imageology between that on 5-mm-thick sections and 1-mm-thick sections (P = 0.001 < 0.05). It is suggested that the use of 2-mm slice thickness is suitable in revealing second-fourth generation bronchi and the use of 1-mm slice thickness is suitable in revealing fifth-eighth generation bronchi.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call