Abstract

We propose an automatic nodule registration method between baseline and follow-up chest CT scans. Initial alignment using the center of the lung volume corrects the gross translational mismatch, and rigid registration using coronal and sagittal maximum intensity projection images effectively refines the rigid motion of the lungs. Nodule correspondences are established by finding the most similar region in terms of density as well as the geometrical constraint. The proposed nodule registration method increased the nodule hit rate (the ratio of the number of successfully matched nodules to total nodule number) from 26% to 100%.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call