Abstract

The rationale of this study was to investigate the performance of high-resolution CT (HRCT) versus 18F-FDG PET/CT for the diagnosis of pulmonary lymphangitic carcinomatosis (PLC). Methods: In this retrospective institution-approved study, 94 patients addressed for initial staging of lung cancer with suspicion of PLC were included. Using double-blind analysis, we assessed the presence of signs favoring PLC on HRCT (smooth or nodular septal lines, subpleural nodularity, peribronchovascular thickening, satellite nodules, lymph node enlargement, and pleural effusion). 18F-FDG PET/CT images were reviewed to qualitatively evaluate peritumoral uptake and to quantify tracer uptake in the tumoral and peritumoral areas. Histology performed on surgical specimens served as the gold standard for all patients. Results: Among 94 included patients, 73% (69/94) had histologically confirmed PLC. Peribronchovascular thickening, lymph node involvement, and increased peritumoral uptake were more often present in patients with PLC (P < 0.009). Metabolic variables, including tumor SUVmax, SUVmean, metabolic tumor volume, and total lesion glycolysis, as well as peritumoral SUVmax, SUVmean, and their respective ratios to background, were significantly higher in the PLC group than in the non-PLC group (P ≤ 0.0039). Sensitivity, specificity, and area under the receiver-operating-characteristic curve for peribronchovascular thickening (69%, 83%, and 0.76, respectively; 95% confidence interval [95%CI], 0.67-0.85) and increased peritumoral uptake (94%, 84%, and 0.89, respectively; 95%CI, 0.81-0.97) were similar (P = 0.054). For detecting PLC, sensitivity, specificity, and area under the receiver-operating-characteristic curve were significantly higher, at 97%, 92%, and 0.98, respectively (95%CI, 0.96-1.00), for peritumoral SUVmax and 94%, 88%, and 0.96, respectively (95%CI, 0.92-1.00), for peritumoral SUVmean (all P ≤ 0.025). Conclusion: Qualitative evaluation of 18F-FDG PET/CT and HRCT perform similarly for the diagnosis of PLC, with both being outperformed by 18F-FDG PET/CT quantitative parameters.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.