Abstract

In non-smokers, ozone (O3) inhalation causes decreases in forced expiratory volume (FEV1) and dead space (VD) and increases the slope of the alveolar plateau (SN). We previously described a population of smokers with a limited smoking history that had enhanced responsiveness to brief O3 boluses and aimed to determine if responsiveness to continuous exposure was also enhanced. Thirty smokers (19M, 11F, 24±4years, 6±4 total years smoking,4±2packs/week) and 30 non-smokers (17M, 13F, 25±6years) exercised for 1h on a cycle ergometer while breathing 0.30ppm O3. Smokers and non-smokers were equally responsive in terms of FEV1 (−9.5±1.8% vs −8.7±1.9%). Smokers alone were responsive in terms of VD (−6.1±1.2%) and SN (9.1±3.4%). There was no difference in total delivered dose. Dead space ventilation (VD/VT) was not initially different between the two groups, but increased in the non-smokers (16.4±2.8%) during the exposure, suggesting that the inhaled dose may be distributed more peripherally in smokers. We also conclude that these cigarette smokers retain their airway responsiveness to O3 and, uniquely, experience changes in VD that lead to heterogeneity in airway morphometry and an increase in SN.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.