Abstract

In the last decade, spiral computed tomography (CT) and magnetic resonance (MR) angiography (MRA) have become a viable alternative to conventional angiography in the diagnosis of acute pulmonary embolism. However, patients with dyspnea are often unable to hold their breath for a longer time and thus image degradation is frequently observed. Consequently, an imaging sequence that allows free breathing is desirable. The aim of this animal study was to compare contrast-enhanced spiral CT, MRA and a real-time MR sequence, the latter without breath-hold, with pulmonary angiography as reference gold standard. Nine pigs with artificially induced pulmonary embolism underwent this multimodality comparison. All images were independently evaluated for the presence of pulmonary emboli by two reviewers. Forty-three filling defects were detected by conventional angiography on lobar and segmental levels. Sensitivity of CT images was 72.1 and 69.8% for Readers 1 and 2, respectively, and sensitivity of MRA images was 79.1 and 81.4%. With real-time MR imaging, however, the detection rate was 97.7% for both readers. We conclude that, under experimental conditions, real-time MR imaging without the use of radiation or iodinated contrast material is comparable with angiography in the detection of pulmonary emboli.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.