Abstract

A pulmonary artery catheter (PAC) is an important tool in the preoperative cardiac management, and it provides measurements which helps in the patient management During open heart surgery the catheter tends to rest against the anterior lateral wall of the right atrium where the catheter may be caught by a suture in the cannulation for cardiopulmonary bypass. We describe a very rare complication which is inadvertent surgical suturing of the PAC to the inferior vena cava that necessitated reopening the chest, cutting, the suture and removing the catheter.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.