In the range of very low specific speed (nSUBs/SUB<0.25, non-dimensional), the perfomance of a centrifugal pump is much different from that of a centrifugal pump of normal nSUBs/SUB and the efficiency of the pump drops rapidly with the decrease of nSUBs/SUB. In order to examine the reason of unstable performance characteristics of the very low nSUBs/SUB centrifugal pump, the internal flow of the pump with a semi-open impeller is measured by a PTV(Particle Tracking Velocimetry) system. The purpose of this study is to make clear the internal flow characteristics and to obtain basic knowledge of the pump perfornance. The results show that the leakage flow through tip clearance give a strong effect on the flow pattern of impeller passage. A large vortex in the impeller passage and a strong reverse flow at impeller outlet are formed in the range of small flow rates, and the vortex and the reverse flow together reduce the absolute tengential velocity at the impeller outlet and cause the performance instability.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.