Abstract

ABSTRACTIn this paper, modelling and hardware implementation of three-phase interleaved inverter-based shunt active power filter (SAPF) is proposed to mitigate current harmonics, reactive power for ensuring unity power factor and load balancing without shoot-through effect. Shoot-through effect is one of the hazardous issues in conventional voltage source inverters such as damage of power electronic switches, electromagnetic interference, ringing in the power circuitry. The present power system has inevitable non-linear loads which create large variations in the supply voltage distortions. Therefore, the compensation capability and efficiency of the SAPFs degrades. A novel predictive tuned filter is proposed in this paper to estimate the variations in the amplitude of supply voltage, frequency and harmonics for extracting the fundamental voltage signal. The fundamental extracted signal is further processed for reference current generation using generalized p-q theory. The performance of the proposed system is simulated using MATLAB®/Simulink environment and tested under different supply voltage conditions. The simulation results have been validated by developing a prototype in the laboratory by using a dSPACE1104 controller. It is found from the simulated and experimental results that the proposed system is fast, robust and accurate which improves the power quality without shoot-through problem.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call