Abstract

33 Background: PSMA-targeted PET/CT is superior to conventional imaging modalities to localize biochemically recurrent (BCR) PCa after local therapy, particularly in pts with low PSA (<2 ng/mL). However, few studies have reported PSMA-targeted PET/CT accuracy compared to a pre-specified rigorous standard of truth (SOT) including histopathology, correlative imaging or treatment response in this population. Here, we report the CLR and PPV of PSMA-targeted 18F-DCFPyL-PET/CT, for each of the pre-defined SOT criteria for the CONDOR prospective phase 3 study. Methods: The study enrolled men with rising PSA after definitive therapy and negative or equivocal standard of care imaging (e.g., CT/MRI, bone scintigraphy, F-18 fluciclovine). A single 9 mCi (333 MBq) ± 20% dose of 18F-DCFPyL was injected, followed by PET/CT 1-2 hours later. Pts with positive 18F-DCFPyL-PET/CT scans based on local interpretation were scheduled for follow up within 60 days to verify suspected lesion(s) using a composite SOT. The primary endpoint was CLR defined as PPV with the requirement of anatomic lesion co-localization between 18F-DCFPyL-PET/CT and the SOT. The SOT consisted of, in descending priority: 1) histopathology, 2) subsequent correlative imaging findings determined by two central readers, or 3) post-radiation PSA response. The trial was successful if the lower bound of the 95% confidence interval for CLR exceeded 20% for at least two of three independent, blinded central 18F-DCFPyL-PET/CT reviewers. Results: 208 men (median PSA 0.8 ng/mL) underwent 18F-DCFPyL-PET/CT and the study achieved its primary endpoint: CLR was between 84.8% to 87.0% (lower bound of 95% CI: 77.8%-80.4%) among the three 18F-DCFPyL-PET/CT readers, against the composite SOT. The performance of 18F-DCFPyL-PET/CT by CLR (≥1 lesion co-localized) and PPV (≥1 lesion confirmed) was maintained through all 3 SOT categories. Histopathology (N=31): 78.6-82.8% and 92.9-93.3% for CLR and PPV, respectively; correlative imaging (N=100): 86.1-88.6% and 87.0-89.5% for CLR and PPV, respectively; and PSA response (N=1): 100% for both CLR and PPV. Further analyses of the correlative imaging results showed CLR remained high across the different modalities used a) 18F-fluciclovine-PET/CT (N=71): (86.8-90.9%); b) MRI (N=23): (80.0-86.7%); and c) CT (n=6): (80.0-100%). Conclusions: PSMA-targeted 18F-DCFPyL-PET/CT detected and localized metastatic lesions with high CLR and PPV regardless of which criterion defined CLR that was used, in men with BCR who had negative or equivocal baseline imaging. Clinical trial information: NCT03739684.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call