Abstract

Introduction of the Vitek GNS-506 susceptibility testing cards in the Hippokration General Hospital, Thessaloniki, Greece, resulted in an apparently high prevalence of imipenem-resistant Acinetobacter baumannii. When 35 of these isolates were further tested by disk diffusion, broth microdilution, and agar dilution assays, 32 were imipenem sensitive by all tests and three were sensitive or intermediate, depending on the method. The pseudoresistant acinetobacters did not form a genetically homogeneous group. It is suggested that the detection of imipenem-resistant A. baumannii isolates by this system should be confirmed by an additional susceptibility test.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.