Abstract

AbstractA pseudodynamic testing procedure has been applied by which the seismic response of a base‐isolated building is obtained by using as specimen the isolators, while the superstructure is numerically simulated. The procedure also takes advantage of the continuous pseudodynamic testing capabilities of the ELSA laboratory, which increase the accuracy of the results and reduce the strain‐rate effect of the rubber bearings. A simple proportional correction of the measured forces compensates the remaining strain‐rate effect due to the unrealistic speed of the test. The correction factor is obtained by means of a characterizing test on the specific rubber isolators.The developed method has been successfully applied to the prediction of the seismic response of a base‐isolated four‐storey building submitted to several specified accelerograms. The results for those earthquakes as well as the effects of some changes of the parameters of the system are discussed. Copyright © 2002 John Wiley & Sons, Ltd.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.