Abstract

Effect of pseudocritical rapid energy dissipation (PRED) from Pressurizer in nuclear steam supply system of Pressurized Water Reactor, where a single event as common cause failure, of considerable reduction of base-load electricity demand causes the temperature of the reactor coolant system (RCS) to increase, and corresponding pressure increases in pressurizer and steam generators above set-points. The study employed the uses of MATLAB/Simulink library tools, to experimentally modelled pressure control as PRED, where the momentum of transport of kinematic viscosity fraction above pseudocritical point dissipated as excess energy, to maintain the safety of the Pressurizer and RCS and keep the water from boiling. The result demonstrated the significance of pressure vector and Prandlt number as heat transfer coefficients that provided detailed activities in 2-D contour and 3-D graphics of specific internal energy and other parameterization of fluid in the pressurizer.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.