Abstract

A refraction study was performed of 52 pseudophakic subjects implanted with a 3M diffractive intraocular lens (IOL). Twenty patients implanted with conventional monofocal IOLs from 3M were used as controls. The refraction for distance and near was determined, corresponding to the refractive (distance vision) and diffractive (near vision) foci. Pseudoaccommodation amplitude was measured relative to the variation of visual acuity as a function of “fogging” obtained with plus and minus lenses over any required spherical cylindrical power. Results showed that the 3M diffractive IOL acted as a bifocal lens in all subjects except those whose IOLs had decentered markedly. The dioptric range allowing good vision for distance and near is much wider with the diffractive IOL than it is with a monofocal IOL. Almost perfect vision, and the satisfaction of the patients, was achieved when the distance refraction was near to emmetropia and astigmatism was minimal. However, hyperopic biometric inaccuracies were less disturbing than myopic inaccuracies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.