Abstract

Pulse-compression is a correlation-based measurement technique successfully used in many nondestructive evaluation applications to increase the signal-to-noise ratio in the presence of huge noise, strong signal attenuation or when high excitation levels must be avoided. In thermography, the pulse-compression approach was firstly introduced in 2005 by Mulavesaala and co-workers [1], and then further developed by Mandelis and co-authors that applied to thermography the concept of the thermal-wave radar developed for photothermal measurements [2-3]. Since then, many measurement schemes and applications have been reported in the literature by several groups by using various heating sources, coded excitation signals, and processing algorithms. The variety of such techniques is known as pulse-compression thermography or thermal-wave radar imaging.Even despite the continuous improvement of these techniques during these years, the advantages of using a correlation-based approach in thermography are still not fully exploited and recognized by the community. This is because up to now the reconstructed thermograms' time sequences after pulse-compression were affected by the so-called sidelobes, i.e. the temperature time trends of the pixels exhibit oscillations, especially in the cooling stage, so that they do not reproduce the output of a standard thermography measurement. This is a severe drawback since it hampers an easy interpretation of the data and their comparison with other thermography techniques.To overcome this issue and unleash the full potential of the approach, this paper shows how it is possible to implement a pulse-compression thermography procedure capable of suppressing any sidelobe by using a pseudo-noise excitation and a proper processing algorithm.At the end of the procedure, time-sequences of thermograms are reconstructed that correspond to the sample response to a well-defined virtual excitation, namely a rectangular pulse, making the pulse-compression procedure “transparent”. This allows the analysis of pixel time trends by using thermal theory-driven processing such as thermal signal reconstruction, pulsed-phase thermography, etc. Moreover, by tuning the characteristic of the pseudo-noise excitation, it is possible to pass from simulating a very short excitation pulse, retrieving results analogous to pulsed-thermography, to simulating long-pulse excitation to match the sample spectral characteristics maximizing the signal-to-noise ratio. This makes the procedure very flexible and extremely attractive in many applications such as high-attenuating materials, characterization of fast thermal phenomena, and inspection of fragile samples inspection, e.g. paintings or other artworks, etc.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.