Abstract

In order to study how to improve the spatial action of precast monolithic composite floor slabs, and examine replacing the cast-in-place surface layer for reducing the weight of structure, we used pseudo-dynamic tests on one-quarter scale models of two-span and three-story frame structures. The lateral load tests compared the stresses and displacements with a cast-in-place floor frame–shear wall structure (SJ1) and a precast monolithic floor frame–shear wall structure with X horizontal braces at the bottom of the floor (SJ2). The results show the X horizontal braces can improve the spatial action. Structural integrity (SJ2) as well as the effective transmission of the horizontal force can be ensured by additional X bracing at the bottom of the rigidity of the floor without a cast-in-place concrete topping. The results show that X horizontal braces more effectively transfer horizontal stress, which provides a beneficial reference for similar research.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.