Abstract

A Si(Li) solid state detector, CsI, LiF thermoluminescence dosimeters (TLD), and fast film were used to measure proton fluence, energy distribution, and depth dose in a cubical Lucite phantom exposed to beams of 20, 35, and 45 MeV protons. The recoiled deuterons and scattered protons from a deuteron gas chamber were used as a beam monitor during irradiation of the animals. The depth-dose measurements illustrate that thermoluminescence dosimeters can be used to estimate proton exposures in a Lucite phantom for 20-45 MeV protons. It also appears that TLD is relatively energy independent over this energy interval. Young Beagle dogs' eyes (100 days old) were exposed to 70, 125, 240, and 480 surface rads. The average dose to iris, lens and retina was calculated from the surface dose and the depth-dose curves. The maximum dose to the lens and retina was about 4.5 times the surface dose, respectively, for 35 MeV and 45 MeV protons. The maximum dose to the iris for the 20 MeV protons was about 2.6 times the surfa...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.