Abstract
This study aimed to evaluate methods for infants' physical activity measurement based on accelerometry, including the minimum number of measurement days and placement of a wrist or ankle device. We also evaluated the acceptability of the device among infants and mothers. A cross-sectional mixed-methods study was conducted on a convenience sample of 90 infants. Physical activity was measured using the Actigraph GT3X+ accelerometer placed on the wrist and/or ankle for 7 consecutive days (worn for 24 h), and a qualitative interview was performed to verify acceptability. The intraclass correlation coefficient (ICC) method and the Bland and Altman's dispersion diagram were used to verify the minimum number of measurement days. All analyses were stratified by walking status. The mean (SD) age was 12.9 (1.70) months; the mean acceleration varied between 25.8 mg (95% confidence interval (CI), 14.3-52.7) and 27.3 mg (95% CI, 17.9-44.5) using the wrist placement, and between 24.9 mg (95% CI, 10.6-48.4) and 26.2 mg (95% CI, 11.7-65.6) using the ankle placement. The ICC results showed a lower acceleration variability between days among infants incapable of walking; they achieved an ICC of 0.80 with 1 d of measurement in both placements. Among those capable of walking, the minimum number of days to achieve an ICC of 0.80 was 2 d measured at the wrist (0.85; 95% CI, 0.71-0.93) and 3 d measured at the ankle (0.92; 95% CI, 0.84-0.96). The qualitative results pointed to the wrist placement as the preferred placement among the overall sample. Two and three measurement days with the accelerometer placed on the wrist and ankle, respectively, seemed to adequately represent a week of measurement. The accelerometer placed on the wrist had better acceptance by the infants and mothers.
Highlights
Health benefits attributed to physical activity among adults and adolescents are well established [1,2]
Parent reports have a low agreement with objective measures, which is mainly due to an overestimation of the measure [7,8]
The use of motion sensors, especially accelerometers, has been established as a viable physical activity measurement in young children, because it is an objective measure of body movement and less prone to bias compared with subjective measures [9]
Summary
Health benefits attributed to physical activity among adults and adolescents are well established [1,2]. In this context, an important challenge is how to measure physical activity with such a young sample. There is a need to discuss the most appropriate methods regarding physical activity measurement among young children using accelerometry, by verifying accuracy of the measures and by considering the acceptability of the device in the infants_ daily life. The present study aims to determine the most appropriate methods for physical activity measurement among infants on the basis of accelerometry, including the minimum number of days of measurement required, placement of the device on the wrist or ankle, and acceptability of the device
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.