Abstract

Herein, by utilizing ionic liquid, we have shown for the first time that activated carbon can be used as a cheap and recyclable peroxidase mimic in the construction of colorimetric sensors for biomedical applications. The purposed nanozyme catalyzed the oxidation of 3,3′,5,5′-tetramethylbenzidine (TMB) in the presence of hydrogen peroxide (H2O2) to produce a blue colored product which can be monitored at 652nm. H2O2 is the oxidative product of glucose in the presence of glucose oxidase. Therefore, the oxidation of glucose can be quantitatively related to the colorimetric response by combining these two reactions. Under the optimal experimental conditions, a linear response was observed for glucose concentrations ranging from 12 to 550μmol/L, with a detection limit of 3.5μmol/L. Furthermore, the specificity of the proposed method was demonstrated against common interfering compounds including uric acid, ascorbic acid, lactose, sucrose and maltose. The applicability of the proposed method was demonstrated for glucose detection in human serum samples. The proposed methodology can serve as a general way to design ionic liquid based nanozyme mimetics for various catalytic reactions and colorimetric sensing applications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call