Abstract

Development and validation of early-response radiation injury biomarkers are critical for effective triage and medical management of irradiated individuals. Plasma protein and haematological profiles were evaluated using multivariate linear-regression analysis to provide dose-response calibration curves for photon-radiation dose assessment in 30 rhesus macaques total-body-irradiated to 1-8.5 Gy with (60)Co gamma rays (0.55 Gy min(-1)). Equations for radiation dose received were established based on different combinations of protein biomarkers [i.e. C-reactive protein (CRP), serum amyloid A (SAA), interleukin 6 (IL-6) and Flt3 Ligand (Flt3L)] at samples collection time-points 6 h, 1, 2, 3, 4 and 7 d post-total-body irradiation. Dynamic changes in the levels of CRP, SAA, IL-6 and Flt3L may function as prognostic indicators of the time course and severity of acute radiation sickness (ARS). The combination of protein biomarkers provides greater accuracy for early radiation assessment than any one biomarker alone.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.