Abstract
Abstract In this study, protective Ti coatings were deposited on the CoSb 3 substrate by DC magnetron sputtering to prevent the sublimation of Sb. The microstructure of Ti coating was observed by SEM and AFM. The thermal aging behaviors of coated CoSb 3 samples were investigated through accelerated aging at 650 °C for 24 h. The results indicated that Ti coatings were columnar crystals and body-centered cubic structure. The preferred orientation of Ti film was along the crystal plane of (0 0 2). The thickness of Ti film increased with the deposition time increasing. The weight loss decreased with the thickness of Ti coating increasing. Compared with the uncoated CoSb 3 material, the degradation of thermoelectric properties for coated CoSb 3 samples decreased slowly after accelerated thermal aging test.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.