Abstract

In the article the dependence of protective efficiency of the respiratory protective devices on the filter penetration coefficient and leakage of the polluted air through sealing band was established. The leakage was determined by the ratio of the filter resistance and the sealing band. The relationship between increasing the filter resistance and worsening the protective effectiveness of respiratory protective device was established. Factors that worsen the respirator quality were determined: the gaps between the face and half-mask, weak tension of the head harness. Filter parameters that will ensure high efficiency for respirators of the second protection class were established.