Abstract

Above deck, cables on naval ships are exposed to high-intensity radiated fields and nuclear electromagnetic pulse (NEMP) that may cause conducted interference and generate electromagnetic fields that exceed the immunity levels of commercially available equipment above and below deck. Exposed cables, such as open power plugs or lighting cables, are modeled and characterized both as a monopole antenna perpendicular to the deck and as a transmission line, representing a cable close to the deck. The placement of an illuminated cable close to the deck is a good protection measure for long cables at low frequencies, which includes NEMP protection. The coupled pulse from a high-intensity NEMP illumination is not expected to cause damage on electric installations. It is shown that for exposed cable length of maximum 25 cm and not placed in the line of sight of transmitters above 400 MHz, no additional protection measures are needed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.