Abstract
Prosthetic valve removal for reoperative valve replacement is time consuming and has a risk of damage to the heart because of severe adhesions. Prosthetic valves can be removed quickly, easily, and safely by using an ultrasonic scalpel (Harmonic Scalpel, Ethicon Endo-Surgery, Cincinnati, OH). The space between the prosthesis and the native annulus was carefully dissected using Harmonic Synergy blades connected to an Ethicon Gen11 Generator at energy level 5. The average time for prosthetic valve removal using an ultrasonic scalpel was 6 minutes 11 seconds. No patient required new permanent pacemaker implantation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.