Abstract

Prosthetic valve endocarditis is a significant infection. It is often serious, and may result in a complicated course leading to valvular malfunction. We present the case of a 50-year-old male with an aortic Medtronic Hall valve, who presented with loss of his normal metallic click. A transthoracic echocardiogram confirmed the diagnosis of endocarditis and of an aortic-root abscess. Blood cultures were positive for nutritionally deficient Streptococcus. He underwent successful surgery and later was discharged. Patients with mechanical heart valves are often bothered by the metallic sound. It can interfere with their daily life. However, the loss of the click may indicate valvular dysfunction, dehiscence of the prosthesis, and/or tissue infection with abscess formation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.